USAfixTM - Repair Guide (RG) - Master Email RG
- Test Pump Voltage at Power Board
 Level of Difficulty - MEDIUM  Estimated Completion Time - 15 minutes
TASKI - SWINGO 5000

Tools Required
Tool 
Volt meter (True RMS capable)
Wrench-Allen metric 4.0mm

Parts Required


Step Procedure & Parts & Tools
1 Either have water in tank, or adjust water sensor to show orange and green LED's on a dry hose.

2 Access Power Board and bypass seat switch

3 Disable drive by removing Black (negative) Drive Cable from Power Board. Use 4mm Allen Wrench
Wrench-Allen metric 4.0mm

4 locate pump connector on board

5 Insert needle probes into Red and Blue wires
Volt meter (True RMS capable)

6 Activate brush and solution system to full settings

7 Press pedal down...pump should show 24+V on full setting - gradually decreasing with lower settings. Approx 15-16V at Setting 1.